Constructed of color-coded synthetic oil, ozone and water resistant rubber (EPDM) insulation and an oil resistant thermoset chlorinated polyethylene (CPE) jacket, SOOW is rated for indoor/outdoor use.

Is so cord suitable for wet locations?

Also suitable for indoor and outdoor use, for use in dry locations not to exceed min. -40°C or max. 90°C, wet locations and other applicable locations; or when exposed to oil or coolant at temperatures not to exceed 60°C.

Is so cable tray rated?

Commonly run in suspended basket tray or ladder racking, Tray Cable has superior UV, moisture, and oil resistant properties. … TC cables are rated for 600 volts and can be used in industrial power or control circuits, where flame retardant cables are desired.

What is the difference between so and SJO cord?

The insulation thickness is the main difference, with the extra hard service “SO” cables requiring thicker insulation to accommodate for higher voltage ratings, while the SJO constructions require thinner insulation with their lower voltage rating.

Is Sjoow cable sunlight resistant?

The heavy-duty rubber jacket in this cable is made of chlorinated polyethylene elastomer (CPE) and is resistant to water, oil, sun, and heat. This allows the SJOOW cable to be used for both indoor and outdoor applications.

What cable is suitable for dry locations only?

Type AC cable is approved by the NEC for use only in dry locations. In order to comply with the NEC for use in wet locations, interlocked Type MC Cable must have a corrosion resistant jacket and wet location rated conductors.

Is so cord sun resistant?

SOOW is incredibly durable. Its thermoset rubber jacket makes the cord weather resistant, and the jacket hardens under a direct application of heat, which allows the cord to be unaffected by aging, abrasion, water, sunlight and ozone. Oil-resistant insulation and jacketing lend to the cord’s durability as well.

What is so cable used for?

SO cord can be operated in both inside and outside environments. Common applications include wiring for industrial machinery, enormous appliances, heavy-duty tools, motors, and temporary electrical power and lighting for construction sites.

What does so mean in so cable?

The “S” in “SO” means “stranded” or “service wire.” Cables so designated are suited for heavy duty industrial tasks requiring 600 volts.

Is SJT cord outdoor rated?

Type SJT, but rated or outdoor use at -31° F. Type S, but also rated oil resistant. Type SO, but also rated for outdoor use at -31° F. Thermoplastic parallel cord for light duty, 300 volts.

Article first time published on

Is cable tray mechanical protection?

Cable ladder systems and cable tray systems are designed for use as supports for cables and not as enclosures giving full mechanical protection. They are not intended to be used as ladders, walk ways or support for people as this can cause personal injury and also damage the system and any installed cables.

Is tray cable rated for direct burial?

Approved for direct burial and outdoors in cable trays where sunlight resistant is required. Also may be installed in wet or dry locations or in areas exposed to chemicals and oils.

Is Thhn tray rated?

THHN tray cable comes in a variety of wire gauge sizes and conductors. One of the most common ones is the 4-3C THHN-PVC tray cable with ground. This cable is also known as the multi-conductor THHN cable. It is rated at 90°C dry, 75°C wet and it provides outstanding sunlight, cold bend, and cold impact resistance.

What's the difference between Sjoow and Soow?

The main difference between these portable cords is their voltage ratings. SJOOW is a Junior Service Cord, which means it only has a voltage rating of 300V. SOOW Cable, on the other hand, has a rating of 600V. … SOOW cable is also more resistant to impact, abrasion, and ozone.

Is SJO cord waterproof?

These cables have a jacket made of thermoplastic elastomer (TPE). … Just like it sounds, the outer jacket of the cable is oil resistant. OO – The addition of the extra “O” means that the outer jacket and the insulation are both oil resistant. W – Weather and Water Resistant.

What does Sjoow cable stand for?

SJOOW stands for: S = Service Cord (600 Volts) J = Junior Service Cord (300 Volts) OO = Oil Resistant both inside insulation and outside jacket. W = CSA designation for weather/water resistance.

What type of wire is Soow?

Therefore SOOW cord is a service cord that is constructed with an oil-resistant black thermoset polyethylene (CPE) jacket with color-coded synthetic oil, ozone and water resistant rubber (EPDM) insulation. The durability of SOOW cord is a result of the components of the jacket and insulation material.

What size so cord is good for 100 amps?

When it comes to the lines connecting master and secondary panels, where the line will carry as much as a full 100 amps, use a 2-gauge non-metallic sheathed electrical cable. The cable must contain one or two hot wires depending on your needs, one neutral wire, and one ground wire. Each wire should be 2-gauge in size.

What kind of wire is in Soow?

This SOOW cord features 18-10 AWG fully annealed stranded tinned copper conductors, EPDM insulation, and Super Vu-Tron® Supreme jacketing.

Can I use armored cable outdoors?

The interlocking metal tape armor Type MC cable is required to have a bare or insulated equipment grounding conductor in addition to any other conductors within the cable. … These cables can be installed either indoors or outdoors and in exposed and concealed locations.

What type of wire should be used outdoors?

Exposed or buried wiring must be listed for its application. (Type UF cable is the most commonly used nonmetallic cable for residential outdoor wiring runs.) UF cable can be direct buried (without conduit) with a minimum of 24 inches of cover.

What wire is Cannot be used in wet locations?

As an example, two of the most common types of wire used in residential projects are THHN and THWN. THHN is thermoplastic, highly heat-resistant (up to 90 degrees C.), and nylon-jacketed. It is not suitable for wet locations.

Is Soow cable rated for direct burial?

Since it is subject to physical damage, it is not allowed as a direct burial. UF cable is used for direct burial. “SOOW” cord is not rated for direct burial on the exterior insulation.

What is the voltage rating of SJO cord?

An SJO cord is flexible since its core consists of stranded conductors, but it only has a 300V rating. This makes the SJO cord ideal for lighter work than its more powerful 600-volt counterparts.

What voltage rating does Stoow carry?

Sycor Part NoAWGVoltage RatingSTOOW12412600STOOW10210600STOOW10310600STOOW10410600

What type of cable is so?

SO cable is one of the most popular and versatile portable electrical cords made today. These are multi-conductor cords, comprised of 2 or more conductors, which can be used in both indoor and outdoor applications.

What kind of cord can be used for portable appliances?

Cord sets used with portable electric tools and appliances must be of the three-wire type and must be designed for hard or extra-hard use. Examples of flexible cords designed for hard or extra-hard use include hard service cord types S, ST, SO, STO and junior hard service, SJ, SJO, SJT, SJTO.

What is VW-1 rated?

VW-1: Recognized by both UL and CSA standards, this is a 3,000 BTU/hr vertical flame test and can be performed on both the completed lengths of bulk cable or jacketed single conductors. For reference, a 3,000 BTU/hr burner is approximately the same size as a Bunsen burner.

What does Sjeow mean?

Cord TypeJacketVoltage RatingSJEOWElastomer300SJEOOWElastomer300SJTThermoplastic300SJTOThermoplastic300

What does VW-1 mean on an extension cord?

VW-1 = Flame retardant. FT2 = Flame retardant.

Is cable tray an exposed conductive part?

The cable tray carries metallic sheathed cables, such as bare micc. – In the event of a fault on the circuit the fault path will be the metallic sheath of the cable and therefore the tray is not an exposed-conductive-part and does not require earthing.